Starter Motor


Hitachi Mitsubishi
Type SS114-87 MW-V1R
Constant 30" 30"

No Load


Hitachi Mitsubishi
Terminal voltage (V) 12 11
Ampere (A) Less than 60 Less than 60
Rotation (r.p.m.) More than 7000 More than 4800



Loaded


Hitachi Mitsubishi
Terminal voltage (V) 6.3 6
Ampere (A) Less than 420 Less than 470
Torque (Kg.m) More than 0.9 More than 0.68

General Information


Hitachi Mitsubishi
Voltage for pinion out Less than 8 Less than 9
Clearance shaft & bushing Front Less than 0.2mm Less than 0.2mm
Clearance shaft & bushing Medium Less than 0.45mm -
Clearance shaft & bushing Rear Less than 0.03-0.1mm Less than 0.2mm
Alignment of shaft (Limit) Less than 0.1mm Less than 0.1mm
Out dia. Of commutator (Standard) 33mm 33mm
Diameter wear limit of commutator Less than -2.0mm Less than -2.0mm
Run-out limit of commutator Less than 0.2mm Less than 0.2mm
Amendable accuracy of commutator Less than 0.05mm Less than 0.05mm
Depth mica More than 0.2mm More than 0.2mm
Brush height 16mm 15mm
Wear limit 9.5mm 7mm
Spring tension (Standard) 800g + or - 15% 800g + or - 15%
Weakness limit Up to 700g Up to 700g

Starter Motor (Hitachi)

  1. Ass'y-armature
  2. Washer-thrust
  3. Ass'y-pinion
  4. Stopper-pinion
  5. Clip-stopper
  6. Washer-stopper
  7. Bearing-centre
  8. Ass'y-cover, rear
  9. Brush (+)
  10. Brush (-)
  11. Screw 3Ø
  12. Bolt-through
  1. Lever-shift
  2. Pin-lever
  3. Pin-cotter
  4. Ass'y-switch, magnetic
  5. Cover dust
  6. Packing
  7. Bolt
  8. Ass'y cover
  9. Screw
  10. A'ssy-coil, field
  11. Screw